The Effect of Misalignment to Vibration, Electric Current and Shaft Rotation Speed on The Coupling Transmision

Romiyadi Romiyadi, Purnama Irwan

Abstract


Coupling is one of the components are widely used in various industries. Coupling is widely used as a power transfer transmission. Coupling have a long life time, it mean coupling was damage if out of the maintenance. The one factor is misalignment. This study aim to determine the effect of misalignment on the coupling transmission to vibration, electric current and shaft rotation speed. In this study, was done alignment process with variations of misalignment on the coupling transmission and was done measurement value of vibration,  electric current and shaft rotation speed. The study results show that the changed of misalignment would give a positive impact to vibration and electric current. For the effect misalignment to shaft rotation speed, the study results show that the changed of misalignment would give a negative impact to shaft rotation speed.

Keywords


Misalignment, Coupling, Vibration, Electic Current, Shaft Rotation Speed

Full Text:

PDF

References


Amrullah dan Aminuddin, “Rancang Bangun Media Pembelajaran Praktik Alignment,” Jurnal Sosial Humaniora dan Pendidikan, vol. 2(1), pp. 59-63.

I.A. Raharjo., A. Widodo., I. Haryanto “Analisis Misalignment Kopling Pada Mesin Rotary Menggunakan Sinyal Getaran Steady State dengan Metode Rim and Face,” Jurnal Teknik Mesin, vol. 4(1), pp. 214-223.

D.D. Dharmawan., A. Widodo., I. Haryanto, “Misalignment Kopling Dengan Analisis Sinyal Getaran Kondisi Steady State Menggunakan Metode Reverse,” Jurnal Teknik Mesin, vol. 4(1), pp. 197-206.

A.I. Tauvana, “Alignment Coupling dengan Metode Double Diarim and Face,” Jurnal Simetris, vol. 9(1), pp. 671-678.

Phase II Machine Tools, Inc. 2008. Digital Vibration Tester Model No. DVM 1000 : Operation Manual. New Jersey : Phase II Machine & Tool, Inc.


Refbacks

  • There are currently no refbacks.


Copyright of JTM (p-ISSN: 2089-4880   e-ISSN:2598-8263)